CAll Us: +1(212)-966-0410

  • A variable zoom microscope is used to obtain same image size on screen for any given capillary size.
  • The ideal tool for cross checking of incoming spinerrettes against specifications

  • A variable zoom microscope is used to obtain same image size on screen for any given capillary size.
  • The ideal tool for cross checking of incoming spinerrettes against specifications

  • A self-calibration is automatically performed before every inspection using a NIST traceable reticle before which provides maximum accuracy and repeatability.
  • Ideal solution for process/quality certifications such as ISO.
  • Optional provision for counterbore viewing is possible (available on select models)

  • A self-calibration is automatically performed before every inspection using a NIST traceable reticle before which provides maximum accuracy and repeatability.
  • Ideal solution for process/quality certifications such as ISO.
  • Optional provision for counterbore viewing is possible (available on select models)

  • User selected pass-fail criteria is easily established by selecting measurements, tolerances, acceptable failed capillaries, and number of acceptable plugged capillaries.
  • Inspects capillaries ranging from 0.020mm to 5.0mm in diameter.
  • Inspects capillaries ranging from 0.1:1 to 25:1 in length:diameter ratio at speeds of up to 0.35 seconds per capillary.

  • User selected pass-fail criteria is easily established by selecting measurements, tolerances, acceptable failed capillaries, and number of acceptable plugged capillaries.
  • Inspects capillaries ranging from 0.020mm to 5.0mm in diameter.
  • Inspects capillaries ranging from 0.1:1 to 25:1 in length:diameter ratio at speeds of up to 0.35 seconds per capillary.

  • Inspects all types of capillaries, including complex cross sections and multilocular cross sections. Inspection time remains same for all capillary shapes for any number of measurements.
  • Remote diagnostics allow troubleshooting or upgrades without a service call.

  • After automatic inspection, each Spinneret is objectively qualified as either “Passed” or “Failed”, according to the selected inspection criteria.
  • Automatic correctional and focusing algorithms are built into the software, allowing inspection of warped and convex Spinnerets.

  • After automatic inspection, each Spinneret is objectively qualified as either “Passed” or “Failed”, according to the selected inspection criteria.
  • Automatic correctional and focusing algorithms are built into the software, allowing inspection of warped and convex Spinnerets.

  • Inspection data is stored for data analysis, using pictorial and graphical representation to provide insight into the cleaning and extrusion processes.
  • Automatic air purge cleans annoying dirt, fingerprints, cleaning beads, and other debris from the capillaries before the inspection is completed.

  • Inspection data is stored for data analysis, using pictorial and graphical representation to provide insight into the cleaning and extrusion processes.
  • Automatic air purge cleans annoying dirt, fingerprints, cleaning beads, and other debris from the capillaries before the inspection is completed.

  • Inspection review tools include on-screen capillary images, measurement data, free roam control, and report generation.
  • Capillary illuminator provides immediate visual identification of defective capillaries using a laser pointing device.

  • Inspection review tools include on-screen capillary images, measurement data, free roam control, and report generation.
  • Capillary illuminator provides immediate visual identification of defective capillaries using a laser pointing device.

  • Automatic learn feature – A software feature of the SpinTrak™ that learns new capillary patterns and sizes by scanning the Spinneret in low magnification.

features8

  • Automatic learn feature – A software feature of the SpinTrak™ that learns new capillary patterns and sizes by scanning the Spinneret in low magnification.

features8

  • Unique capability of checking capillaries perpendicularly.

  • Unique capability of checking capillaries perpendicularly.

  • Advanced dirt detection capability of detecting dirt on the capillary exits and deep inside the capillary.

  • Advanced dirt detection capability of detecting dirt on the capillary exits and deep inside the capillary.

  • Provision to visually inspect any random Object other than spinnerets at high magnification.

  • Provision to visually inspect any random Object other than spinnerets at high magnification.

  • Built-in automatic marking system marks the failed capillaries with an erasable dye (available as an option)

  • Built-in automatic marking system marks the failed capillaries with an erasable dye (available as an option)